Underground Storage Tank System Repair/Retrofit for Code Compliance (LC) -- Bring an existing, #2 diesel fuel, underground storage tank (UST) system into compliance with current GA State environmental and fire codes (GA § 391-3-15 and GA § 120-3-11), as follows:
1) Perform all work in general accordance with 29 CFR 1910 (OSHA), ensure compliance with MUTCD requirements for vehicular and pedestrian traffic controls, and maintain proper housekeeping.
2) Replace the existing underground, single-wall, supply and return piping with new double-wall piping, using materials that meet or exceed the above referenced code requirements.
3) Replace existing underground fuel tank accessory equipment with new tank accessory equipment, using materials that meet or exceed the above referenced code requirements, and in accordance with the equipment manufacturers' requirements.
4) Retrofit the existing, single-wall UST, by installing a double-wall fiberglass-reinforced plastic (FRP) tank shell within the existing tank, using a GA Environmental Protection Division (EPD) approved system.
5) Perform post-installation testing and inspections, as required by GA EPD, to demonstrate proper operation of the repaired/retrofitted UST system.
6) Restore the excavation and surface pavement in a manner equivalent to, and/or more substantial than original install.
7) Prepare and submit reporting/documentation to GA EPD, as required.
Surface pavement removal (approximately 230-sq ft) and excavation needed to access the underground piping and the top of the UST are within the facility's property line.
Application Square Footage 230
Professionals on this permit American Containment Services, Inc. (General contractor)
2026-09-29
Underground Storage Tank System Repair/Retrofit -- Bring an existing, #2 diesel fuel, underground storage tank (UST) system into compliance with current GA State environmental and fire codes (GA § 391-3-15 and GA § 120-3-11), as follows:
1) Perform all work in general accordance with 29 CFR 1910 (OSHA), and in accordance with good engineering practices.
2) Replace the existing underground, single-wall, supply and return piping with new double-wall piping, using materials that meet or exceed the above referenced code requirements.
3) Replace existing underground fuel tank accessory equipment with new tank accessory equipment, using materials that meet or exceed the above referenced code requirements.
4) Retrofit the existing, single-wall UST, by installing a new, double-wall fiberglass-reinforced plastic (FRP) tank shell within the existing tank, using a GA Environmental Protection Division (EPD) approved system.
5) Perform post-installation testing and inspections, as required by GA EPD, to demonstrate proper operation of the new UST system components.
6) Prepare and submit reporting/documentation to GA Environmental Protection Division, as required.
7) Throughout performance of the work, ensure constant compliance with MUTCD requirements for vehicular and pedestrian traffic controls, and maintain proper housekeeping.
2026-08-31
DRAGON CON - 265 PEACHTREE CENTER NE AVE
More Than 4 Stories or Floors No
Status changes we observed OTHER (August 31, 2026) → CLOSED (September 3, 2026)
2026-08-27
HABITAT FOR HUMANITY AFFILIATED CONFERENCE - 265 PEACHTREE CENTER NE AVE
More Than 4 Stories or Floors No
2026-07-31
No description on file.
Certificate of Occupancy No
Status changes we observed PENDING (July 31, 2026) → CLOSED (August 3, 2026)
2026-07-23
NABJ 2026 - 265 PEACHTREE CENTER NE AVE
More Than 4 Stories or Floors No
2026-07-02
Encore Group USA LLC -- We are an audio-visual equipment and rental service company. We only do business with hotel clients/guests that are hosting an event (conference, meeting, etc.) that requires audio visual needs for their event. We have a contract with the hotel for a small office (100 sq feet), therefore we do not rent or lease. We share a space with the hotel. We are a separate company from the hotel.
Have you received Zoning Approval No