System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete blocks vertical instead of horizontal so the air handler sets higher
Dampers- 2-12"
Bypass- 1-10"
Lineset- 1-30'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- Yes
Rough walk notes:
Venthood- Yes “6 *10’ then the sidewall (Pipe needs to be 4” below the box
Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
*lock box 8246
*Metal Plenums *Bubble Wrap
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent
*Need metal wire on dryer vent for support (No black webbing)
*Leave tyton for bath fans
*Need to install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan
*Lockbox- 4342
FLEX TAKEOFF:
R6: 12"-3, 10"-4,8"-4, 6"-5, 4"-4
Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
TRIM WORK ORDER
*Lockbox- 8246
*Need a 6403K Aprilaire Zoneboard
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
Status changes we observed PENDING (August 27, 2026) → ISSUED (August 28, 2026)
2026-08-18
44 Hood Drive SE -- GPS:1096 HOOD DRIVE SW ATLANTA GA 30310
System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete blocks vertical instead of horizontal so the air handler sets higher
Dampers- 2-12"
Bypass- 1-10"
Lineset- 1-30'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- Yes
Rough walk notes:
Venthood- Yes “6 *10’ then the sidewall (Pipe needs to be 4” below the box
Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough
*Metal Plenums *Bubble Wrap
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent
*Need metal wire on dryer vent for support (No black webbing)
*Leave tyton for bath fans
*Need to install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan(ROOF)
*Lockbox: 8246
FLEX TAKEOFF:
R6: 12"-3, 10"-6,8"-5, 6"-5, 4"-4
Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
TRIM WORK ORDER
*Lockbox- 8246
*Need a 6403K Aprilaire Zoneboard
*add registers to vents in attic 2-4"
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
2026-08-18
44 Hood Drive SE -- GPS:1096 HOOD DRIVE SW ATLANTA GA 30310
System Placement- 2.5 Ton Zone in Attic Goes in walk in attic
Dampers- 2-12"
Bypass- 1-10"
Lineset- 1-50'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- Yes
Rough walk notes:
Venthood- Yes “6 *10’ then the sidewall (Pipe needs to be 4” below the box
Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough
*Metal Plenums *Bubble Wrap
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent
*Need metal wire on dryer vent for support (No black webbing)
*Leave tyton for bath fans
*Need to install AprilAire 8145 Fresh Air Fan(ROOF)
*Lockbox: 8246
FLEX TAKEOFF:
R6: 12"-4, 10"-5,8"-6, 6"-5, 4"-4
Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
TRIM WORK ORDER
*Lockbox- 8246
*Need a 6403K Aprilaire Zoneboard
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
2026-07-29
Lot 42 Hood Drive SW -- GPS:1096 HOOD DRIVE SW ATLANTA GA 30310
System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete blocks vertical instead of horizontal so the air handler sets higher
Dampers- 2-12"
Bypass- 1-10"
Lineset- 1-30'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- Yes
Rough walk notes:
Venthood- Yes “6 *10’ then the sidewall (Pipe needs to be 4” below the box
Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough
*Metal Plenums *Bubble Wrap
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent
*Need metal wire on dryer vent for support (No black webbing)
*Leave tyton for bath fans
*Need to install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan(ROOF)
*Lockbox: 8246
FLEX TAKEOFF:
R6: 12"-3, 10"-6,8"-5, 6"-5, 4"-4
Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
TRIM WORK ORDER
*Lockbox- 8246
*Need a 6403K Aprilaire Zoneboard
*add registers to vents in attic 2-4"
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
Status changes we observed PENDING (July 29, 2026) → ISSUED (July 30, 2026)
2026-07-29
Lot 41 Hood Drive -- GPS:1096 HOOD DRIVE SW ATLANTA GA 30310
System Placement- 2.5 Ton Zone in Attic Goes in walk in attic
Dampers- 2-12"
Bypass- 1-10"
Lineset- 1-50'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- Yes
Rough walk notes:
Venthood- Yes “6 *10’ then the sidewall (Pipe needs to be 4” below the box
Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough
*Metal Plenums *Bubble Wrap
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent
*Need metal wire on dryer vent for support (No black webbing)
*Leave tyton for bath fans
*Need to install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan(ROOF)
*Lockbox: 8246
FLEX TAKEOFF:
R6: 12"-4, 10"-5,8"-6, 6"-5, 4"-4
Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)
TRIM WORK ORDER
*Lockbox- 8246
*Need a 6403K Aprilaire Zoneboard
*add registers to vents in attic 2-4"
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
Status changes we observed PENDING (July 29, 2026) → ISSUED (July 30, 2026)