2026-09-10
1236 Grant St -- This application addresses violations cited in City of Atlanta Violation Correction Notice dated 7/29/2021 (Ch. 1, §103.1) and related Stop Work Order/Legal Notices dated 2/19/2021 and 7/14/2021, for work performed without permits at 1236 Grant St SE: iron fence, land disturbance, basement refinish, electrical, HVAC, plumbing, new water lines, and foundation/waterproofing repair. This building permit covers foundation footing, CMU block wall, waterproofing, backfill, and concrete cap per Stability Engineering stamped drawings, together with the iron fence, land disturbance, and basement refinish work cited above. Electrical, HVAC, plumbing, and new water line work cited on the same notices are being addressed under separate trade permits to be filed by the licensed contractors of record. All items cited in the referenced notices are being brought into compliance.
2026-09-10
1236 Grant St (RES) -- This application addresses violations cited in City of Atlanta Violation Correction Notice dated 7/29/2021 (Ch. 1, §103.1) and related Stop Work Order/Legal Notices dated 2/19/2021 and 7/14/2021, for work performed without permits at 1236 Grant St SE: iron fence, land disturbance, basement refinish, electrical, HVAC, plumbing, new water lines, and foundation/waterproofing repair. This building permit covers foundation footing, CMU block wall, waterproofing, backfill, and concrete cap per Stability Engineering stamped drawings, together with the iron fence, land disturbance, and basement refinish work cited above. Electrical, HVAC, plumbing, and new water line work cited on the same notices are being addressed under separate trade permits to be filed by the licensed contractors of record. All items cited in the referenced notices are being brought into compliance.
Reported project value $25,000
Scope Code R1 Single Family Residence
Application Square Footage 1228
2026-08-10
Soltis Basement Repair -- FOOTING INSTALLATION
? Excavate and prepare the site for footing installation per Stability Engineering drawing dimensions and
specifications.
? Install reinforced concrete footings to the depth, width, and elevation shown in the drawings.
? Ensure proper alignment, level, and structural integrity of all footings.
? Verify all dimensions and elevations with provided drawings prior to concrete placement.
? Stability Engineering shall inspect and approve footing installation in writing before proceeding to
block installation.
4. BLOCK INSTALLATION
? Supply and install concrete blocks per Stability Engineering drawing specifications and quantities.
? Blocks shall be laid level, plumb, and properly aligned with specified dimensions.
? Fill block cores with grout or concrete as required by the design engineer.
? Maintain proper mortar joint thickness and workmanship per building code standards.
? Stability Engineering shall inspect and provide written approval before proceeding to waterproofing.
5. WATERPROOFING
? Apply complete waterproofing membrane or coating system to exterior of block wall per manufacturer
and engineer specifications.
? Ensure all seams, joints, cracks, and penetrations are properly sealed to prevent water infiltration.
? Verify that waterproofing system complies with project specifications and local building codes.
? Provide all labor and materials necessary for complete waterproofing coverage.
6. STONE BACKFILL & COMPACTION
? Supply and place #57 stone as drainage layer and backfill material per drawing specifications.
? Properly compact stone in lifts to achieve specified density and grading.
? Provide skilled labor for stone placement and mechanical compaction.
? Provide all equipment rental and operation necessary for complete backfill installation per project
schedule.
7. CONCRETE CAP
? Supply and install concrete cap from top of block wall to existing house footing per Stability Engineering
drawings.
? Finish concrete cap to specified smoothness and slope for proper drainage.
? Cure concrete cap per industry standards to ensure durability and strength.
? Provide all labor and materials for proper cap installation and finishing.
8. SITE CLEANUP & WASTE MANAGEMENT
? Provide jobsite dumpster/dump trailer for all debris and waste materials.
? Cover all dumpster/dump trailer rental and disposal fees.
? Maintain clean and safe work area daily throughout project duration.
Reported project value $35,000
Scope Code R1 Single Family Residence
Application Square Footage 1228
2026-08-10
Soltis Repair (RES) -- Installation of new reinforced concrete footings and CMU block foundation wall, per Stability Engineering drawings (Sheets S-0.0, S-0.1, S-1.0, S-2.0), including waterproofing membrane, #57 stone drainage backfill, and concrete cap tying into existing house footing. Work includes excavation, footing and block installation, exterior waterproofing, compacted stone backfill, and concrete cap finish, all per engineered drawings and inspected at each stage by the design engineer.
Reported project value $25,000
Scope Code Residential Site Work
Application Square Footage 1000
2026-08-03
Soltis Repair -- Installation of new reinforced concrete footings and CMU block foundation wall, per Stability Engineering drawings (Sheets S-0.0, S-0.1, S-1.0, S-2.0), including waterproofing membrane, #57 stone drainage backfill, and concrete cap tying into existing house footing. Work includes excavation, footing and block installation, exterior waterproofing, compacted stone backfill, and concrete cap finish, all per engineered drawings and inspected at each stage by the design engineer.