2026-09-08
Tela Residence Addition (RES) -- THIS PROJECT CONSISTS OF A RESIDENTIAL ALTERATION AND MINOR ADDITION TO AN EXISTING 1 STORY SPLIT LEVEL
SINGLE-FAMILY DWELLING. FINISH FLOOR ELEVATIONS REMAIN UNCHANGED.
THE SCOPE INCLUDES:
REMOVAL AND REPLACEMENT OF THE EXISTING ROOF, INCLUDING 50% OF STRUCTURAL FRAMING PRESERVING 50% OF
EXISTING FRAMING. R-42 ROOF : ALL NEW ROOF DECK, 2" OF RIGID POLY ISO INSULATION , COVERBOARD & TPO MEMBRANE
ABOVE DECK WITH R-30 MINERALWOOL BELOW DECK.
COMPLETE REMOVAL AND REPLACEMENT OF ALL EXISTING EXTERIOR WALL CLADDING WITH JAMES HARDIE ARTISAN
VERTICAL SHIPLAP PLANK.
MINOR ADDITION OF 38 SQUARE FEET OF CONDITIONED FLOOR AREA WITHIN NE EXISTING CORNER OF THE STRUCTURE.
INSTALLATION OF NEW FOUNDATION ELEMENTS AND REINFORCEMENTS TO SUPPORT UPDATED ROOF LOADS AND NEW
INTERIOR SUPPORT COLUMNS.
RECONFIGURATION OF SELECT INTERIOR FRAMING AND FINISHES TO COORDINATE WITH NEW LAYOUT AND STRUCTURAL
CHANGES.
UPDATED HVAC DUCTWORK AND PLUMBING LINES AS REQUIRED TO ACCOMMODATE THE NEW FRAMING.
INSULATION AND ENVELOPE UPGRADES TO MEET CURRENT IECC ENERGY CODE REQUIREMENTS (ROOF, WALLS, FLOORS).
INSULATION OF BASEMENT WALLS WITH 2" XPS INSULATION INSIDE FACE OF CMU AND ENCAPSULATION OF BASEMENT AND
CRAWL SPACE.
NO CHANGE TO ZONING SETBACKS
Reported project value $490,000
Scope Code R1 Single Family Residence
Application Square Footage 2134
Professionals on this permit Andrew DaCosta (General contractor)
2026-09-02
1919 Wellbourne Dr NE -- THIS PROJECT CONSISTS OF A RESIDENTIAL ALTERATION AND MINOR ADDITION TO AN EXISTING 1 STORY SPLIT LEVEL
SINGLE-FAMILY DWELLING. FINISH FLOOR ELEVATIONS REMAIN UNCHANGED.
THE SCOPE INCLUDES:
REMOVAL AND REPLACEMENT OF THE EXISTING ROOF, INCLUDING 50% OF STRUCTURAL FRAMING PRESERVING 50% OF
EXISTING FRAMING. R-42 ROOF : ALL NEW ROOF DECK, 2" OF RIGID POLY ISO INSULATION , COVERBOARD & TPO MEMBRANE
ABOVE DECK WITH R-30 MINERALWOOL BELOW DECK.
COMPLETE REMOVAL AND REPLACEMENT OF ALL EXISTING EXTERIOR WALL CLADDING WITH JAMES HARDIE ARTISAN
VERTICAL SHIPLAP PLANK.
MINOR ADDITION OF 38 SQUARE FEET OF CONDITIONED FLOOR AREA WITHIN NE EXISTING CORNER OF THE STRUCTURE.
INSTALLATION OF NEW FOUNDATION ELEMENTS AND REINFORCEMENTS TO SUPPORT UPDATED ROOF LOADS AND NEW
INTERIOR SUPPORT COLUMNS.
RECONFIGURATION OF SELECT INTERIOR FRAMING AND FINISHES TO COORDINATE WITH NEW LAYOUT AND STRUCTURAL
CHANGES.
UPDATED HVAC DUCTWORK AND PLUMBING LINES AS REQUIRED TO ACCOMMODATE THE NEW FRAMING.
INSULATION AND ENVELOPE UPGRADES TO MEET CURRENT IECC ENERGY CODE REQUIREMENTS (ROOF, WALLS, FLOORS).
INSULATION OF BASEMENT WALLS WITH 2" XPS INSULATION INSIDE FACE OF CMU AND ENCAPSULATION OF BASEMENT AND
CRAWL SPACE.
NO CHANGE TO ZONING SETBACKS
2026-08-08
No description on file.
Professionals on this permit AYALA TREE SERVICES LLC (General contractor)
2026-08-08
No description on file.