2026-09-25
BLD-26-0528340
· Commercial Building Alterations (Renovations) · IN_PROGRESS
This is a retail tenant inside the International Plaza Shopping Center. Interior build-out of a mercantile space contained within an existing shell building
2026-09-18
26TMP-075243
· Commercial Building Alterations (Renovations) · OTHER
No description on file.
2026-09-10
Demo existing suite subsystem back to 6" mall main. Install new 4" system for tenant buildout. 34 fire sprinklers, David Yurman Space 267.
Professionals on this permit WAYNE AUTOMATIC FIRE SPRINKLERS, INC (Licensed Professional)
2026-09-03
Fire Alarm System Modifications for new tenant Space 267 David Yurman at International Plaza. New power supply panel, smoke detector, control modules and notification devices to be installed. GC Permit #BLD-26-0526404.
Professionals on this permit APG ELECTRIC, LLC (Licensed Professional)
2026-09-02
BLD-26-0527792
· Commercial Building Alterations (Renovations) · IN_PROGRESS
The project consists of the interior demolition and minor associated renovations of an existing tenant space located within International Plaza Mall, Space 125B, Tampa, Florida. The space was formerly part of the Express tenant space and will be converted to a temporary shell condition pending a future tenant build-out.
The scope of work includes demolition of existing interior partitions, finishes, ceilings, lighting and power systems, storefront system, and tenant signage. Work shall generally include the following:
Demolish existing interior walls, ceilings, fixtures, and finishes within the existing demising wall boundaries of Space 125B.
Remove the existing tenant storefront system and signage and provide temporary closure as indicated on the drawings.
Modify the existing fire sprinkler system as required to accommodate the new exposed ceiling shell condition throughout the space.
Demolish existing tenant plumbing systems and fixtures and provide capped utility connections at the rear of the space for future tenant use. The existing plumbing fixture count will be reduced from four (4) fixtures to zero (0). Abandoned plumbing located above the space and associated with previous food court tenants shall also be removed or properly abandoned where accessible during demolition.
Demolish the existing tenant mechanical distribution system back to the existing VAV systems and leave building HVAC connections as indicated for the temporary shell condition and future tenant build-out.
Completely demolish the existing tenant electrical distribution, lighting, and power systems. Provide a new electrical service and panel(s) at the rear of the space for future tenant build-out as indicated on the electrical drawings.
No tenant occupancy is proposed as part of this permit. The completed space will remain in a temporary unoccupied shell condition until construction of a future tenant improvement under a separate permit.
2026-08-13
Inspections cannot be fully approved without TCO
Professionals on this permit ECKINGER CONSTRUCTION CO. (General contractor)
2026-08-13
Fats track permit to add/ relocate less than 20 fire sprinklers in David Yurman, space 231.
Professionals on this permit WAYNE AUTOMATIC FIRE SPRINKLERS, INC (General contractor)