2026-10-07
building #2 unit C -- rough and trim new house. lockbox#8246
Building Type New
Total Square Footage 1200
Professionals on this permit BRIGHTEN ELECTRIC INC (General contractor)
Status changes we observed PENDING (October 7, 2026) → ISSUED (October 7, 2026)
2026-10-07
2439 FAIRBURN ROAD SW UNIT 2-D -- System Placement- 2 Ton in Attic*Horizontal *Need to turn the concrete blocks horizontal x2 so the air handler sets higher
Dampers- 2-12"
Bypass- 10"
Lineset-1-30'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- No
Venthood- 6” Venthood *Need to frame 4” below the box
Bath fans- 3-4" **(2- Cornice, 1- Sidewall)
Rough work order notes:
*run drain line with lineset
*Metal Plenums
*All R6
*Install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan
*Need to run 6” AprilAire 8145 Fresh Air Vent to the roof *Needs to be 10’ from any exhaust
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent-roof
*Leave tyton for bath fans
*Lockbox- 8246
FLEX TAKEOFF
R6: 3-4”, 5-6”, 4-8”, 6-10”, 2-12”
(3-Cornice, 1- Sidewall)
*dryer out of roof
TRIM WORK ORDER
*Lockbox- 8246
*Need (2)s900 white
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
2026-10-07
2439 Fairburn Road SW Unit 2-C -- System Placement- 2 Ton in Attic*Horizontal *Need to turn the concrete blocks horizontal x2 so the air handler sets higher
Dampers- 2-12"
Bypass- 10"
Lineset-1-30'x3/4"
B-vent- No
Waterheater- No
Floor boots- No
14" Flex- No
Venthood- 6” Venthood *Need to frame 4” below the box
Bath fans- 3-4" **(2- Cornice, 1- Sidewall)
Rough work order notes:
*run drain line with lineset
*Metal Plenums
*All R6
*Install (1) 4SA and (1) 4RA in the attic
*Need to install AprilAire 8145 Fresh Air Fan
*Need to run 6” AprilAire 8145 Fresh Air Vent to the roof *Needs to be 10’ from any exhaust
*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE
*Need to tape ALL seams on dryer vent-roof
*Leave tyton for bath fans
*Lockbox- 8246
FLEX TAKEOFF
R6: 3-4”, 5-6”, 4-8”, 6-10”, 2-12”
(3-Cornice, 1- Sidewall)
*dryer out of roof
TRIM WORK ORDER
*Lockbox- 8246
*Need (2)s900 white
Scope Code R1 Single Family Residence
Building Type New
Professionals on this permit STUART MECHANICAL SERVICES INC (General contractor)
2026-10-07
building #2 unit D -- rough and trim new house. lockbox#8246
Building Type New
Total Square Footage 1200
Professionals on this permit BRIGHTEN ELECTRIC INC (General contractor)
Status changes we observed PENDING (October 7, 2026) → ISSUED (October 7, 2026)
2026-10-05
2439 Fairburn Rd -- New plumbing installation
Scope Code R2 Duplex
Building Type New
Professionals on this permit KLS PLUMBING, INC. (General contractor)
Status changes we observed PENDING (October 5, 2026) → ISSUED (October 6, 2026)
2026-07-24
2439 Fairburn Rd SW, Atlanta GA 30331-Bldg 1 unit B -- Installation of Water and Sewer
Professionals on this permit L. B. RAINEY GEN MAINTENANCE & CONSTRUCTION. (General contractor)
2026-07-24
2439 Fairburn Rd SW, Atlanta GA 30331-Bldg 1 unit A -- Installation of Water and Sewer
Professionals on this permit L. B. RAINEY GEN MAINTENANCE & CONSTRUCTION. (General contractor)
2026-07-24
2439 Fairburn Rd SW, Atlanta GA 30331-Bldg 2 unit C -- Installation of Water and Sewer
Professionals on this permit L. B. RAINEY GEN MAINTENANCE & CONSTRUCTION. (General contractor)
2026-07-24
2439 Fairburn Rd SW, Atlanta GA 30331-Bldg 2 unit D -- Installation of Water and Sewer
Professionals on this permit L. B. RAINEY GEN MAINTENANCE & CONSTRUCTION. (General contractor)
2026-07-20
o -- temp pole
Building Type New
Total Square Footage 1200
Professionals on this permit BRIGHTEN ELECTRIC INC (General contractor)
2026-07-20
o -- temp pole
Building Type New
Total Square Footage 1200
Professionals on this permit BRIGHTEN ELECTRIC INC (General contractor)