2026-10-22
PLAN REVISION #4 NARRATIVE:
1. SHEET D4.1 (detail section DS-01):
Replace perimeter CMU wall tie-beams CAD-2 with 3 rows of grouted/reinforced bond beams at 2nd floor and roof levels.
2. SHEET D4.2 (detail section DS-02):
i. Replace perimeter CMU wall tie-beam CAD-1 with 3 rows of grouted/reinforced bond beams at roof level.
ii. Revised structural framing detail provided for transition from 2nd floor bedroom to exterior balcony.
3. SHEET D4.3 (detail section DS-03):
Replace perimeter CMU wall tie-beam CAD-1 with 3 rows of grouted/reinforced bond beams at roof level.
4. SHEET D4.4 (detail section DS-04):
Replace perimeter CMU wall tie-beam CAD-1 with 3 rows of grouted/reinforced bond beams at roof level.
5. SHEET D4.5 (detail sections DS-05 & DS-06):
Replace perimeter CMU wall tie-beams CAD-1 with 3 rows of grouted/reinforced bond beams at 2nd floor and roof levels.
6. SHEET S5.2 (1st floor lintel & dowel layout):
i. Added concrete beam T04 at 2nd floor transition from bedroom to exterior balcony. Replacement of 1 each CMU-filled cell KA1 with 1 each concrete column K1.
ii. Concrete column D1 “as-built” (12”x23” in lieu of 12”x12”).
iii. Partial deletion of CMU entry wall. Replacement of 1 each CMU-filled cell KA1 with 1 each concrete column K1.
7. SHEET S5.3 (2nd floor lintel & dowel layout):
i. Added CMU wall/reinforced filled cells KA1 along 2nd floor transition from bedroom to exterior balcony.
ii. Concrete column D1 “as-built” (12”x23” in lieu of 12”x12”).
iii. Partial deletion of CMU entry wall. Replacement of 1 each CMU-filled cell KA1 with 1 each concrete column K1.
Professionals on this permit RBS SERVICES CORP (Licensed Professional)
2026-08-19
1. SHEET S5.1 (continuous strip footing detail):
Foundation CMU stem wall shall be reinforced vertically with 1 #5 at 48” on centers, stem wall to be fully grouted. Top #5 @ 48” on center rebar dowel “hook” profile eliminated. Bottom of wall footing to be 12” min. from natural/undisturbed grade. Provide monolithic slab-on-grade thickened concrete 8” x 16” “bell” profile at interior load-bearing framed walls.
2. SHEETS S5.2 and S5.3 (1st and 2nd floor lintel & dowel layouts):
i. K1 (8”x8” cast-in-place column) and KA1 (CMU filled cell reinforcement) revised plan layout provided.
ii. CAD-1 (alternate) detail provided for 8”x8” pre-cast lintel option in lieu of 8”x8” cast-in-place lintels.
Professionals on this permit OLIVA ENGINEERING, INC (Licensed Professional)