Contractor: STUART MECHANICAL SERVICES INC

5 permits on file
Matched by exact contractor name -- most contractor records have no license number to key off of, so name-formatting variations (e.g. "ACME Roofing" vs "ACME Roofing LLC") won't be linked together automatically.
Permit types
All HVAC (5)

Permit History

2026-07-23
BM-202603405 · HVAC · ISSUED · 3861 STRATFORD PARK DR NE
Renew Permit # BM-202400712 -- 3861 STRATFORD PARK DRIVE NE System placement- 4 Ton ZONE Main Level, Upstairs in Mech Room Zoned- Yes Zone Dampers- 2-12", 1-14" Bypass- 1-12" Lineset- 1-30'x7/8" B-vent- No Waterheater- No Floor boots- No 14" Flex- Yes Venthood- No Bathfans- 5-4" (4- Cornice, 3- Sidewall) *Metal Plenums *All R6 Flex *All wall returns need to be 12" off of the ground *Seal ALL seams on dryer vent with tape and mastic *Dryer vent is going to be a stackable *Need tytons for all bath fan
2026-07-23
BM-202603408 · HVAC · ISSUED · 2092 TIMBALL RD NW
System Change Out -- Replace existing unit with new 2.5 ton Trane heat pump. Update zone board and dampers.
2026-07-22
BM-202603386 · HVAC · ISSUED · 2134 LARCHWOOD RD SW
2134 Larchwood Road SW -- GPS: 2134 Larchwood Road Atlanta,ga System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete block Horizontal Dampers- 2-12" Bypass- 1-10" Lineset- 1-30'x3/4" B-vent- No Waterheater- No Floor boots- No 14" Flex- Yes Rough walk notes: Venthood- Yes “6 sidewall (Pipe needs to be 4” below the box) Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough *Metal Plenums *Bubble Wrap *SEAL ALL CONNECTIONS LIKE RIGHT CHOICE *Need to tape ALL seams on dryer vent *Need metal wire on dryer vent for support (No black webbing) *Leave tyton/tape for bath fans *Need to install (1) 4SA and (1) 4RA in the attic *Need to install AprilAire 8145 Fresh Air Fan *Lockbox: 8246 FLEX TAKEOFF: R6: 12"-3, 10"-4,8"-4, 6"-5, 4"-4 Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall) TRIM WORK ORDER *Lockbox- 8246 *Need a 6403K Aprilaire Zoneboard *add registers to vents in attic 2-4"
2026-07-21
BM-202603375 · HVAC · ISSUED · 698 FOREST TRL NW
698 Forest Trail NW -- Add a 6" supply and 8" return to newly addition on main floor. System is in crawl and accessible from below. Job marked and ready for install. Material needed: 1-6"-R8 1-8"-R8 1-8" and 6" collar 1-10x4 floor boot(90) 1-12x4 floor boot(90)
2026-07-16
BM-202603281 · HVAC · ISSUED · 2561 WESTMINISTER HEATH NW
Renew permit# BM-202502920 -- Need to run (40') 1" underground from the meter to the pool heater Ditch is already dug Need to install tracer wire and air test Install (1) 1" whole home regulator for the existing house