HVAC

BM-202603386 · filed 2026-07-22

Permit

Type on fileResidential - HVAC
Description2134 Larchwood Road SW -- GPS: 2134 Larchwood Road Atlanta,ga System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete block Horizontal Dampers- 2-12" Bypass- 1-10" Lineset- 1-30'x3/4" B-vent- No Waterheater- No Floor boots- No 14" Flex- Yes Rough walk notes: Venthood- Yes “6 sidewall (Pipe needs to be 4” below the box) Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough *Metal Plenums *Bubble Wrap *SEAL ALL CONNECTIONS LIKE RIGHT CHOICE *Need to tape ALL seams on dryer vent *Need metal wire on dryer vent for support (No black webbing) *Leave tyton/tape for bath fans *Need to install (1) 4SA and (1) 4RA in the attic *Need to install AprilAire 8145 Fresh Air Fan *Lockbox: 8246 FLEX TAKEOFF: R6: 12"-3, 10"-4,8"-4, 6"-5, 4"-4 Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall) TRIM WORK ORDER *Lockbox- 8246 *Need a 6403K Aprilaire Zoneboard *add registers to vents in attic 2-4"
Estimated valueNot on file
Original filingView on city site →

Application Information

Scope CodeR1 Single Family Residence
Building TypeNew
Building Permit NumberBB-202508466
(0)
HEATING SYSTEM (1)
Capacity2.5 Ton Zone
Quantity1
ManufacturerRheem
HEATING SYSTEMUp to 500,000 Per System

Property

Address2134 LARCHWOOD RD SW, Atlanta 30310
Parcel ID14 01800011006

Contractor

GeneralSTUART MECHANICAL SERVICES INC (JOSE ANTONIO GALVAN)
License001023
Phone📞 7708131316

History (2 captures)

List update 2026-07-22 16:13:49.018438+00:00
Status: ISSUED
First captured -- nothing to compare against yet.
Detail fetch 2026-07-23 03:16:38.770081+00:00
Status: ISSUED
address: 2134 LARCHWOOD RD SW, ATLANTA GA 30310None
application_information: {'Scope Code': 'R1 Single Family Residence', 'Building Type': 'New', 'Building Permit Number': 'BB-202508466'} (new field)
application_information_table: {'': [], 'HEATING SYSTEM': [{'Capacity': '2.5 Ton Zone', 'Quantity': '1', 'Manufacturer': 'Rheem', 'HEATING SYSTEM': 'Up to 500,000 Per System'}]} (new field)
block_lot_subdivision: {} (new field)
date_filed: 2026-07-22None
description: GPS: 2134 Larchwood Road Atlanta,ga System Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete block Horizontal Dampers- 2-12" Bypass- 1-10" Lineset- 1-30'x3/4" B-vent- No Waterheater- No Floor boots- No 14" Flex- Yes Rough walk notes: Venthood- Yes “6 sidewall (Pipe needs to be 4” below the box) Bath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough *Metal Plenums *Bubble Wrap *SEAL ALL CONNECTIONS LIKE RIGHT CHOICE *Need to tape ALL seams on dryer vent *Need metal wire on dryer vent for support (No black webbing) *Leave tyton/tape for bath fans *Need to install (1) 4SA and (1) 4RA in the attic *Need to install AprilAire 8145 Fresh Air Fan *Lockbox: 8246 FLEX TAKEOFF: R6: 12"-3, 10"-4,8"-4, 6"-5, 4"-4 Bath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall) TRIM WORK ORDER *Lockbox- 8246 *Need a 6403K Aprilaire Zoneboard *add registers to vents in attic 2-4"None
detail_fields: {'Owner': 'SECRETARY OF HOUSING & URBAN DEVELOPMENT\n*', 'Project Description': '2134 Larchwood Road SW\nGPS: 2134 Larchwood Road Atlanta,ga\nSystem Placement- 2.5 Ton Zone in Attic *Horizontal *Need to turn the concrete block Horizontal\nDampers- 2-12"\nBypass- 1-10"\nLineset- 1-30\'x3/4"\nB-vent- No\nWaterheater- No\nFloor boots- No\n14" Flex- Yes\n\nRough walk notes:\nVenthood- Yes “6 sidewall (Pipe needs to be 4” below the box)\nBath fans- 3-4" **(2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)*all bath fans need to be straight with no turns, builder will mount exhaust fans before rough\n*Metal Plenums *Bubble Wrap\n*SEAL ALL CONNECTIONS LIKE RIGHT CHOICE\n*Need to tape ALL seams on dryer vent\n*Need metal wire on dryer vent for support (No black webbing)\n*Leave tyton/tape for bath fans\n*Need to install (1) 4SA and (1) 4RA in the attic\n*Need to install AprilAire 8145 Fresh Air Fan\n*Lockbox: 8246\n\nFLEX TAKEOFF:\nR6: 12"-3, 10"-4,8"-4, 6"-5, 4"-4\nBath Fans- (2- 4" Sidewall, 2- 4" Cornice, 1- 6" Sidewall)\n\nTRIM WORK ORDER\n*Lockbox- 8246\n*Need a 6403K Aprilaire Zoneboard\n*add registers to vents in attic 2-4"', 'Licensed Professional': 'JOSE ANTONIO GALVAN\nSTUART MECHANICAL SERVICES INC\n001023\n5267 PALMERO COURT\nBUFORD, GA, 30518\nHome Phone:\n7708131316\nMECH CONT CR109618'} (new field)
detail_url: https://aca-prod.accela.com/ATLANTA_GA/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=26BLR&capID2=00000&capID3=12233&agencyCode=ATLANTA_GA&IsToShowInspection=None
fee_data: {'line_items': [], 'total_outstanding': None} (new field)
parcel_number: 14 01800011006 (new field)
project_name: 2134 Larchwood Road SWNone
record_number: BM-202603386None
record_status: Issued (new field)
record_type: Residential - HVACNone
status: IssuedNone
View full history & open as full page ↗