← Back to leads
PENDING

BUILDING

BB-202605976 · filed 2026-07-08

Permit

Type on fileCommercial Alteration
DescriptionRAYONIER INC. / SUITES 2200 (COM) (CO) -- RENOVATION OF EXISTING BUILDING SUITES ON THE 22ND AND 23RD LEVELS OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS FINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL / ELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED RENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS, NOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.
Estimated value$5,066,600
Original filingView on city site →

Application Information

Will trees be destroyed?No
Application Square Footage31491
STRUCTURE, ESTABLISHMENT OCC (1)
Occ StatusProp New
Code Edition2024
Previous UseCommercial
Proposed UseCommercial
Occupant Load511
Fire SprinklerYes
Fire Sprinkler TypeNFPA13
Type of ConstructionIBC- TYPE I-A SPRINKLERED CONST
IBC Occupancy ClassificationIBC Group B Business

Property

Address3280 PEACHTREE RD NE, Atlanta 30305
Parcel ID17 0062 LL754

Owner

Mailing address3500 Lenox Rd NE #250, Atlanta GA 30326

Contractor

GeneralRand Construction Corporation (Manish Shukla)
Phone📞 770-777-4177

History (2 captures)

List update 2026-07-20 01:02:23.064105+00:00
Status: PENDING
First captured -- nothing to compare against yet.
Detail fetch 2026-07-20 02:11:32.233862+00:00
Status: PENDING
address: 3280 PEACHTREE RD NE, ATLANTA GA 30305None
application_information: {'Will trees be destroyed?': 'No', 'Application Square Footage': '31491'} (new field)
application_information_table: {'STRUCTURE, ESTABLISHMENT OCC': [{'Occ Status': 'Prop New', 'Code Edition': '2024', 'Previous Use': 'Commercial', 'Proposed Use': 'Commercial', 'Occupant Load': '511', 'Fire Sprinkler': 'Yes', 'Fire Sprinkler Type': 'NFPA13', 'Type of Construction': 'IBC- TYPE I-A SPRINKLERED CONST', 'IBC Occupancy Classification': 'IBC Group B Business'}]} (new field)
block_lot_subdivision: {} (new field)
date_filed: 2026-07-08None
description: RENOVATION OF EXISTING BUILDING SUITES ON THE 22ND AND 23RD LEVELS OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS FINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL / ELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED RENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS, NOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.None
detail_fields: {'Owner': 'Terminus Venture T100 LLC\n*\n3280 Peachtree Rd NE, Atlanta, GA 30305\nEMAIL: agibbs@cousins.com', 'Project Description': 'RAYONIER INC. / SUITES 2200 (COM) (CO)\nRENOVATION OF EXISTING BUILDING SUITES ON THE 22ND AND 23RD LEVELS OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS\nFINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL /\nELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED\nRENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS,\nNOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.', 'Licensed Professional': 'Manish Shukla\nRand Construction Corporation\n26-1211155\n5565 Glenridge Connector, Suite 650, Sandy Springs, GA 30342\nUnited States\nHome Phone:\n770-777-4177\nGEN CONT GCCO5800'} (new field)
detail_url: https://aca-prod.accela.com/ATLANTA_GA/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=26CAP&capID2=00000&capID3=00ED6&agencyCode=ATLANTA_GA&IsToShowInspection=None
parcel_number: 17 0062 LL754 (new field)
project_name: RAYONIER INC. / SUITES 2200 (COM) (CO)None
record_number: BB-202605976None
record_type: Commercial AlterationNone
status: AcceptedNone
View full history & open as full page ↗