← Back to leads
PENDING

BUILDING

BB-202606039 · filed 2026-07-10

Permit

Type on fileCommercial Alteration
DescriptionRayonier Inc. / Suite 2300 (COM) (CO) -- RENOVATION OF EXISTING BUILDING SUITE ON THE 23RD LEVEL OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS FINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL / ELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED RENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS, NOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.
Estimated value$2,533,300
Original filingView on city site →

Application Information

Will trees be destroyed?No
Application Square Footage10211
STRUCTURE, ESTABLISHMENT OCC (1)
Occ StatusProp New
Code Edition2024
Previous UseOffice
Proposed UseOffice
Occupant Load302
Fire SprinklerYes
Fire Sprinkler TypeNFPA13
Type of ConstructionIBC- TYPE I-A SPRINKLERED CONST
IBC Occupancy ClassificationIBC Group B Business

Property

Address3280 PEACHTREE RD NE, Atlanta 30305
Parcel ID17 0062 LL754

Owner

Mailing address3500 Lenox Rd NE #250, Atlanta GA 30326

Contractor

GeneralRand Construction Corporation (Manish Shukla)
License30342
Phone📞 770-777-1155

History (2 captures)

List update 2026-07-20 00:54:24.372619+00:00
Status: PENDING
First captured -- nothing to compare against yet.
Detail fetch 2026-07-20 01:55:24.141027+00:00
Status: PENDING
address: 3280 PEACHTREE RD NE, ATLANTA GA 30305None
application_information: {'Will trees be destroyed?': 'No', 'Application Square Footage': '10211'} (new field)
application_information_table: {'STRUCTURE, ESTABLISHMENT OCC': [{'Occ Status': 'Prop New', 'Code Edition': '2024', 'Previous Use': 'Office', 'Proposed Use': 'Office', 'Occupant Load': '302', 'Fire Sprinkler': 'Yes', 'Fire Sprinkler Type': 'NFPA13', 'Type of Construction': 'IBC- TYPE I-A SPRINKLERED CONST', 'IBC Occupancy Classification': 'IBC Group B Business'}]} (new field)
block_lot_subdivision: {} (new field)
date_filed: 2026-07-10None
description: RENOVATION OF EXISTING BUILDING SUITE ON THE 23RD LEVEL OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS FINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL / ELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED RENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS, NOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.None
detail_fields: {'Owner': 'TERMINUS VENTURE T100 LLC\n*\n3280 PEACHTREE RD NE\nATLANTA GA 30305\nEMAIL: agibbs@cousins.com', 'Project Description': 'Rayonier Inc. / Suite 2300 (COM) (CO)\nRENOVATION OF EXISTING BUILDING SUITE ON THE 23RD LEVEL OF TERMINUS 100. SCOPE OF WORK FOR THE RENOVATION INCLUDES THE FOLLOWING: DEMOLITION OF EXISTING WALLS\nFINISHES, FLOOR FINISHES, LIGHTING, CEILINGS, MILLWORK AND PLUMBING FIXTURES; NEW WALLS,CEILINGS, LIGHT FIXTURES, FINISHES, MILLWORK, POWER/DATA/AV, FURNITURE, AND MECHANICAL /\nELECTRICAL / PLUMBING (MEP) SYSTEMS. THE BUILDING IS CLASSIFIED AS A BUSINESS (GROUP B) OCCUPANCY, AND THE RAYONIER SUITES FOLLOW THE SAME OCCUPANCY CLASSIFICATION. THE PROPOSED\nRENOVATION SCOPE DOES NOT RESULT IN A CHANGE OF OCCUPANCY, USE, NOR CLASSIFICATION FOR THE OVERALL BUILDING. NEW WORK AS PROPOSED DOES NOT IMPACT EXISTING MEANS OF EGRESS,\nNOR DOES IT REQUIRE THE ADDITION OR MODIFICATION OF PLUMBING FIXTURE COUNTS.', 'Licensed Professional': 'Manish Shukla\nRand Construction Corporation\n26-1211155\n5565 Glenridge Connector, Suite 650, Sandy Springs, GA 30342\n30342\nUnited States\nHome Phone:\n770-777-1155\nGEN CONT GCCO005800'} (new field)
detail_url: https://aca-prod.accela.com/ATLANTA_GA/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=26CAP&capID2=00000&capID3=00EJD&agencyCode=ATLANTA_GA&IsToShowInspection=None
parcel_number: 17 0062 LL754 (new field)
project_name: Rayonier Inc. / Suite 2300 (COM) (CO)None
record_number: BB-202606039None
record_type: Commercial AlterationNone
status: Routed for ReviewNone
View full history & open as full page ↗