← Back to leads
PENDING

DEMOLITION

BB-202606046 · filed 2026-07-10

Permit

Type on fileCommercial Demolition
Description999 PEACHTREE-ACRISURE REMODEL (LC) (CC) -- THIS DEMOLITION SET DOCUMENTS SELECTIVE INTERIOR DEMOLITION OF AN EXISTING TENANT SPACE. WORK INCLUDES DEMOLITION OF NON-LOAD-BEARING PARTITION WALLS, BUILT-IN MILLWORK, CASEWORK, LOCKERS, AND PLATFORMS; REMOVAL OF FLOOR AND WALL FINISHES; REMOVAL OF PLUMBING FIXTURES WITH CAPPING OF SUPPLY/WASTE LINES; DEMOLITION OF CEILING SYSTEMS INCLUDING GRID, TILE, AND GYPSUM BOARD; REMOVAL OF ALL LIGHTING FIXTURES, CURTAIN TRACK, AND LOW-VOLTAGE DEVICES WITH WIRING CAPPED TO SOURCE; AND REMOVAL OF HVAC DIFFUSERS/DUCTWORK AS INDICATED. FIRE/LIFE SAFETY DEVICES TO BE COORDINATED WITH FLS CONSULTANT AND AHJ. ALL DISTURBED SURFACES TO BE PATCHED TO MATCH EXISTING CONDITIONS.
Estimated value$25,000
Original filingView on city site →

Application Information

Will trees be destroyed?No
Application Square Footage4450

Property

Address999 PEACHTREE ST NE, Atlanta 30309
Parcel ID17 01060008051

Owner

NameHINES
Mailing address999 PEACHTREE ST NE, #888, ATLANTA GA 30309

Contractor

GeneralDesignhaus Archtiecture (Peter Stuhlreyer)
Phone📞 248-601-4422

History (2 captures)

List update 2026-07-20 00:54:18.154265+00:00
Status: PENDING
First captured -- nothing to compare against yet.
Detail fetch 2026-07-20 01:48:04.010674+00:00
Status: PENDING
address: 999 PEACHTREE ST NE, ATLANTA GA 30309None
application_information: {'Will trees be destroyed?': 'No', 'Application Square Footage': '4450'} (new field)
application_information_table: {} (new field)
block_lot_subdivision: {} (new field)
date_filed: 2026-07-10None
description: THIS DEMOLITION SET DOCUMENTS SELECTIVE INTERIOR DEMOLITION OF AN EXISTING TENANT SPACE. WORK INCLUDES DEMOLITION OF NON-LOAD-BEARING PARTITION WALLS, BUILT-IN MILLWORK, CASEWORK, LOCKERS, AND PLATFORMS; REMOVAL OF FLOOR AND WALL FINISHES; REMOVAL OF PLUMBING FIXTURES WITH CAPPING OF SUPPLY/WASTE LINES; DEMOLITION OF CEILING SYSTEMS INCLUDING GRID, TILE, AND GYPSUM BOARD; REMOVAL OF ALL LIGHTING FIXTURES, CURTAIN TRACK, AND LOW-VOLTAGE DEVICES WITH WIRING CAPPED TO SOURCE; AND REMOVAL OF HVAC DIFFUSERS/DUCTWORK AS INDICATED. FIRE/LIFE SAFETY DEVICES TO BE COORDINATED WITH FLS CONSULTANT AND AHJ. ALL DISTURBED SURFACES TO BE PATCHED TO MATCH EXISTING CONDITIONS.None
detail_fields: {'Owner': 'HINES\n*\n999 PEACHTREE ST NE\n#888\nATLANTA GA 30309', 'Project Description': '999 PEACHTREE-ACRISURE REMODEL (LC) (CC)\nTHIS DEMOLITION SET DOCUMENTS SELECTIVE INTERIOR DEMOLITION OF AN EXISTING TENANT SPACE. WORK INCLUDES DEMOLITION OF NON-LOAD-BEARING PARTITION WALLS, BUILT-IN MILLWORK, CASEWORK, LOCKERS, AND PLATFORMS; REMOVAL OF FLOOR AND WALL FINISHES; REMOVAL OF PLUMBING FIXTURES WITH CAPPING OF SUPPLY/WASTE LINES; DEMOLITION OF CEILING SYSTEMS INCLUDING GRID, TILE, AND GYPSUM BOARD; REMOVAL OF ALL LIGHTING FIXTURES, CURTAIN TRACK, AND LOW-VOLTAGE DEVICES WITH WIRING CAPPED TO SOURCE; AND REMOVAL OF HVAC DIFFUSERS/DUCTWORK AS INDICATED. FIRE/LIFE SAFETY DEVICES TO BE COORDINATED WITH FLS CONSULTANT AND AHJ. ALL DISTURBED SURFACES TO BE PATCHED TO MATCH EXISTING CONDITIONS.', 'Licensed Professional': 'Peter Stuhlreyer\nDesignhaus Archtiecture\n3300 Auburn Rd. Ste 300\nAuburn Hills, MI, 48326\nUnited States\nHome Phone:\n248-601-4422\nARCH ra011482'} (new field)
detail_url: https://aca-prod.accela.com/ATLANTA_GA/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=26CAP&capID2=00000&capID3=00EK1&agencyCode=ATLANTA_GA&IsToShowInspection=None
parcel_number: 17 01060008051 (new field)
project_name: 999 PEACHTREE-ACRISURE REMODEL (LC) (CC)None
record_number: BB-202606046None
record_type: Commercial DemolitionNone
status: Additional Materials RequiredNone
View full history & open as full page ↗