ELECTRICAL

BE-202604846 · filed 2026-07-15

Permit

Type on fileCommercial - Low Voltage
DescriptionCathedral of Christ the King -- The existing fire alarm panel will be replaced, and that section of the building brought up to code on the 1st floor. The church also wants to add voice evacuation with manual alarm detection with the use of pull stations only in the cathedral area. No smoke or heat detection will be added in the cathedral area due to the usage of incense and smoke during services and funerals. There are also very high ceilings that will not help the detection of smoke or heat. These areas are non-sprinklered and will have smoke detection everywhere except in the cathedral.
Estimated valueNot on file
Original filingView on city site →

Application Information

Total Square Footage15000
Building Permit NumberN/A

Property

Address2699 PEACHTREE RD NE, Atlanta 30305
Parcel ID17 01010001017

Owner

Mailing address680 W PTREE ST NW, ATLANTA GA 30308

Contractor

GeneralDEESCO FIRE PROTECTION (Richard Murphy)
License1245874

History (2 captures)

List update 2026-07-17 13:31:46.721255+00:00
Status: ISSUED
First captured -- nothing to compare against yet.
Detail fetch 2026-07-17 20:16:47.022715+00:00
Status: ISSUED
address: 2699 PEACHTREE RD NE, ATLANTA GA 30305None
application_information: {'Total Square Footage': '15000', 'Building Permit Number': 'N/A'} (new field)
block_lot_subdivision: {} (new field)
date_filed: 2026-07-15None
description: The existing fire alarm panel will be replaced, and that section of the building brought up to code on the 1st floor. The church also wants to add voice evacuation with manual alarm detection with the use of pull stations only in the cathedral area. No smoke or heat detection will be added in the cathedral area due to the usage of incense and smoke during services and funerals. There are also very high ceilings that will not help the detection of smoke or heat. These areas are non-sprinklered and will have smoke detection everywhere except in the cathedral.None
detail_fields: {'Owner': 'ARCHDIOCESE OF ATLANTA\n*\n680 W PTREE ST NW\nATLANTA GA 30308', 'Project Description': 'Cathedral of Christ the King\nThe existing fire alarm panel will be replaced, and that section of the building brought up to code on the 1st floor. The church also wants to add voice evacuation with manual alarm detection with the use of pull stations only in the cathedral area. No smoke or heat detection will be added in the cathedral area due to the usage of incense and smoke during services and funerals. There are also very high ceilings that will not help the detection of smoke or heat. These areas are non-sprinklered and will have smoke detection everywhere except in the cathedral.', 'Licensed Professional': 'Richard Murphy\nDEESCO FIRE PROTECTION\n1245874\n4000 DEKALB TECHNOLOGY PKWY STE\nDORAVILLE, GA, 30340\nLOW VOLT LVU407113'} (new field)
detail_url: https://aca-prod.accela.com/ATLANTA_GA/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=26BLR&capID2=00000&capID3=11871&agencyCode=ATLANTA_GA&IsToShowInspection=None
parcel_number: 17 01010001017 (new field)
project_name: Cathedral of Christ the KingNone
record_number: BE-202604846None
record_type: Commercial - Low VoltageNone
status: IssuedNone